Ask For A Quick Quote

We will contact you within one working day. Please pay attention to your email.

Submit
+
  • 电气化铁路接触网用玻璃绝缘子.jpg

Glass insulators for electrified railway catenary

As an important part of the power transmission system, the stability and reliability of its performance are directly related to the safe operation of the power grid.
  • Commodity name: Glass insulators for electrified railway catenary

Classification:

Mobile:

  • Product Description
  • Main technical parameters of glass insulators for electrified railway catenary (GB and IEC)

    Insulator
    Model
    Nominal
    Diameter
    D
    (Mm)
    Structure
    Height
    H
    (Mm)
    Nominal
    Creepage
    Distance
    L
    (Mm)
    Connection
    Marking
    (Mm)
    Rated machine
    mechanical destruction
    Load
    (kN)
    Pull one by one
    Extension load
    Test
    (kN)
    Power frequency dry
    Tolerance
    Voltage
    (KV)
    power frequency wet
    Tolerance
    Voltage
    (KV)
    Lightning impulse
    Hit tolerance
    Voltage
    (KV)
    Impact
    Voltage Strike
    Wear resistance
    Voltage
    (p.u.)
    Minimum work
    frequency breakdown
    Tolerance
    Voltage
    (KV)
    Radio
    Interference
    10kV
    1MHz
    (μV)
    Visible electricity
    halo voltage
    Feet/Cap
    (KV)
    power frequency electricity
    Arc test
    Insulation
    Sub-list
    slice weight
    Quantity
    (Kg)
    Ruitai Type

    Diameter
    D

    (Mm)


    Spacing
    H

    (Mm)

    Creepage
    Distance
    L

    (Mm)

    Size
    of
    Couplng

    (Mm)

    Mechanical
    Failing
    Load

    (kN)

    Mechanical
    Routine
    Test

    (kN)

    Power
    Frequency
    Withstand
    Voltage
    (DRY)
    (KV)

    Power
    Frequency
    Withstand
    Voltage
    (WET)

    (KV)

    Lighting
    Impulse
    Withstand
    Voltage

    (KV)

    Impulse
    Withstand
    Voltage

    (p.u.)

    Min
    Power
    Frequency
    Puncture
    Voltage

    (KV)

    Radio
    Interference
    Voltage
    (10kV,
    1MHz)
    (μV)

    Crown
    Test
    (pin&cap)

    (KV)
       Power
    Frequency
    Flectric
    Arc Test

    Net
    Weight
    Per
    Unit

    (Kg)
    LXP-70T 255  146  320  Iron cap is 16W\16R
    Ball connection, steel foot
    Connect for 16C
    70  35  70  40  100  2.8  130  ≤50 18/22 0.12s/20kA 4.4 
    LXWP-70T 255  146  400  Iron cap is 16W\16R
    Ball connection, steel foot
    Connect for 16C
    70  35  80  45  110  2.8  130  ≤50 18/22 0.12s/20kA 5.0 
    LXWP1-70T 280  146  450  Iron cap is 16W\16R
    Ball connection, steel foot
    Connect for 16C
    70  35  85  50  125  2.8  130  ≤50 18/22 0.12s/20kA 5.5 
    LXP-80T 255  146  320  Iron cap is 16W\16R
    Ball connection, steel foot
    Connect for 16C
    80  40  70  40  100  2.8  130  ≤50 18/22 0.12s/20kA 4.0 
    LXWP-80T 255  146  400  Iron cap is 16W\16R
    Ball connection, steel foot
    Connect for 16C
    80  40  80  45  110  2.8  130  ≤50 18/22 0.12s/20kA 5.0 
    LXWP1-80T 280  146  450  Iron cap is 16W\16R
    Ball connection, steel foot
    Connect for 16C
    80  40  85  50  125  2.8  130  ≤50 18/22 0.12s/20kA 5.5 