Pollution-resistant disc suspension tempered glass insulator
- Commodity name: Pollution-resistant disc suspension tempered glass insulator
- Product Description
-
Main technical parameters of anti-pollution type-disc suspension tempered glass insulator (GB and IEC)
Insulator type IEC standard insulator Nominal diameter D (mm) Structure height H(mm) Nominal creepage distance L (mm) Connection mark (mm) Rated mechanical damage
Load (kN)Tensile load test one by one (kN) Dry Frequency Dry Withstand Voltage (WET) (kV) Power frequency wet withstand voltage (WET) (kV) Lightning impulse withstand voltage (kV) Impulse overvoltage breakdown withstand voltage (p.u.) Minimum power frequency breakdown withstand voltage (KV) Radio Interference 10kV 1MHz (μV) Power frequency arc test Visible corona foot/cap (kV) Single piece weight of insulator (kg) RaiaiType IEC Type Diameter
D
(Mm)Spacing
H
(Mm)Creepage Distance
(Mm)Sizeof Coupling
(Mm)Mechanical FailingLoad
(kN)Mechanical RoutineTest
(kN)Power Frequency Withstand Voltage (DRY) (kV) Power Frequency Withstand Voltage (WET) (kV) LightingImpulse WithstandVoltage (kV) Impulse Withstanc Voltage
(p.u.)Min PowerFrequency PunctureVoltage (kV) RadioInterference Voltage (10kV,1MHz) (μ V) Power Frequency ElectricArc
TestCorona Test (pin &cap)
(KV)NetWeight PerUnit
(Kg)LXWP4-70 U70BP/146 260 146 400 16 70 35 80 45 110 2.8 130 ≤50 12s/20kA 18/22 5.0 LXWP5-70 U70BP/146 280 146 450 16 70 35 85 50 125 2.8 130 ≤50 12s/20kA 18/22 5.5 LXWP6-70 U70BP/146 320 146 550 16 70 35 90 55 140 2.8 130 ≤50 12s/20kA 18/22 7.5 LXWP3-100 U100BLP/146 260 146 400 16 100 50 80 45 110 2.8 130 ≤50 12s/20kA 18/22 5.0 LXWP4-100 U100BLP/146 280 146 450 16 100 50 85 50 125 2.8 130 ≤50 12s/20kA 18/22 5.0 LXWP6-100 U100BP/146 320 146 550 16 100 50 90 55 140 2.8 130 ≤50 12s/20kA 18/22 7.5 LXWP3-120 U120BLP/146 260 146 400 16 120 60 80 45 110 2.8 130 ≤50 12s/20kA 18/22 5.0 LXWP4-120 U120BLP/146 280 146 450 16 120 60 85 50 125 2.8 130 ≤50 12s/20kA 18/22 5.5 LXWP6-120 U160BSP/146 320 146 550 16 120 60 90 55 140 2.8 130 ≤50 12s/20kA 18/22 7.5 LXWP3-160 U160BP/155 280 155 450 20 160 80 85 50 125 2.8 130 ≤50 12s/20kA 18/22 7.0 LXWP4-160 U160BLP/170 280 170 450 20 160 80 85 50 125 2.8 130 ≤50 12s/20kA 18/22 7.2 LXWP5-160 U160BP/170 320 170 550 20 160 80 90 55 150 2.8 130 ≤50 12s/20kA 18/22 9.2 LXWP6-160 U160BSP/155 320 155 550 20 160 80 90 55 150 2.8 130 ≤50 12s/20kA 18/22 9.0 LXWP7-160 U210BP/146 320 146 550 20 160 80 90 55 150 2.8 130 ≤50 12s/20kA 18/22 8.8 LXWP3-210 U240BP/170 320 170 550 20 210 105 90 55 150 2.8 130 ≤50 12s/20kA 18/22 10.0 LXWP3-240 U240BP/170 320 170 550 24 240 120 90 55 150 2.8 130 ≤50 12s/20kA 18/22 10.5 LXWP4-240 U240BP/170 320 170 550 20 240 150 90 55 150 2.8 130 ≤50 12s/20kA 18/22 10.5 LXWP-300 U300BP/195 390 195 710 24 300 150 95 60 150 2.8 130 ≤50 12s/20kA 18/22 14.0 LXWP3-300 U300BP/195 380 195 635 24 300 150 95 60 150 2.8 130 ≤50 12s/20kA 18/22 14.0 LXWP-420 U420BP/205 380 205 620 28 420 210 90 55 140 2.8 130 ≤50 12s/20kA 18/22 16.5 LXWP-550 U550BP/240 380 240 650 32 550 275 95 55 145 2.8 130 ≤50 12s/20kA 18/22 20.5 LXWP1-550 U550BP/240 380 240 710 32 550 275 95 60 145 2.8 130 ≤50 12s/20kA 18/22 20.5 LXWP-760 U760BP/280 420 280 700 36 760 380 90 55 140 2.8 130 ≤50 12s/20kA 18/22 22 LXWP-840 U840BP/300 420 300 710 40 840 420 95 60 145 2.8 130 ≤50 12s/20kA 18/22 24.5
INQUIRY
* Tip: If you are interested in our products, please leave us a message here, we will contact you within one working day and provide a free quotation, please check your email.
Related Products
Standard type disc suspension tempered glass insulator
Standard insulators, as the name implies, refer to insulators designed, manufactured and widely used in accordance with national or international standards.
DC type disc suspension tempered glass insulator
Toughened glass insulators with excellent pollution resistance, high strength, good self-cleaning and environmental protection characteristics show great application potential and value in the power industry.
Aerodynamic disc suspension tempered glass insulator
As an important part of the power transmission system, the stability and reliability of its performance are directly related to the safe operation of the power grid.
Double Umbrella Disc Suspension Tempered Glass Insulator
As an important part of the power transmission system, the stability and reliability of its performance are directly related to the safe operation of the power grid.