Aerodynamic disc suspension tempered glass insulator
- Commodity name: Aerodynamic disc suspension tempered glass insulator
- Product Description
-
Aerodynamic Type (AC Type): Main Technical Parameters of Disc Suspension Tempered Glass Insulator (GB and IEC)
Insulator type IEC standard insulator Nominal diameter D (mm) Structure height H(mm) Nominal creepage distance L (mm) Connection mark (mm) Rated mechanical damage
Load (kN)Tensile load test one by one (kN) Power frequency dry withstand voltage (kV) Power frequency wet withstand voltage (kV) Lightning impulse withstand voltage (kV) Impulse overvoltage breakdown withstand voltage (p.u.) Minimum work
Frequency breakdown withstand voltage (kV)Radio Interference 10kV 1MHz (μV) Visible corona foot/cap (kV) Power frequency arc test Single piece weight of insulator (kg) RaiaiType IEC Type Diameter
D
(Mm)Spacing
H
(Mm)Creepage Distance
(Mm)Sizeof Coupling
(Mm)Mechanical FailingLoad
(kN)Mechanical RoutineTest
(kN)PowerFrequency WithstandVoltage (DRY) (kV) PowerFrequency WithstandVoltage (WET) (kV) LightingImpulse WithstandVoltage (kV) Impulse Withstanc Voltage
(p.u.)MinPowerFrequency PunctureVoltage (kV) RadioInterference Voltage (10kV,1MHz) (μ V) Corona Test (pin &cap)
(KV)PowerFrequency ElectricArc Test NetWeight PerUnit
(Kg)LXAP-70 U70BP/146M 380 146 365 16 70 35 55 45 90 2.8 130 ≤50 18/22 0.12s/20kA 5.3 LXAP-100 U100BP/146M 380 146 365 16 100 50 55 45 90 2.8 130 ≤50 18/22 0.12s/20kA 5.2 LXAP-120 U120BP/146M 380 146 365 16 120 60 55 45 90 2.8 130 ≤50 18/22 0.12s/20kA 5.4 LXAP-160 U160BP/155M 420 155 380 20 160 80 60 50 95 2.8 130 ≤50 18/22 0.12s/20kA 7.2 LXAP-210 U210BP/17OM 420 170 380 20 210 105 60 50 95 2.8 130 ≤50 18/22 0.12s/20kA 7.3 LXAP-240 U240BP/170M 420 170 380 24 240 120 60 50 95 2.8 130 ≤50 18/22 0.12s/20kA 7.5 Main technical parameters of aerodynamic type (DC type) disc suspension tempered glass insulator (GB and IEC)
Insulator type IEC standard insulator Nominal diameter D (mm) Structure height H(mm) Nominal creepage distance L (mm) Connection mark (mm) Rated mechanical damage
Load (kN)Tensile load test one by one (kN) DC dry withstand voltage (kV) DC wet withstand voltage (kV) Lightning impulse withstand voltage (kV) Impulse overvoltage breakdown withstand voltage (p.u.) Breakdown withstand voltage of SF6 (kV) Radio Interference 10kV 1MHz (μV) DC visible corona voltage foot/cap (kV) Single piece weight of insulator (kg) RaiaiType IEC Type Diameter
D
(Mm)Spacing
H
(Mm)Creepage Distance
(Mm)Size of Coupling
(Mm)Mechanical FailingLoad
(kN)Mechanical RoutineTest
(kN)Anodic DC Dry Withstandvoltage Anodic DC Wet withstandvoltage Lighting Impulse With stand Voltage (kV) Impulse With stanc Voltage
(p.u.)SF6
Puncture withstandVoltageRadioInterference Voltage (10kV,1MHz) (μ V) DC Corona Tes NetWeight PerUnit
(Kg)LXAZP-160 U160BP/146M 420 170 390 20 160 80 140 60 110 2.8 210 ≤50 ≥ 50 10 LXAZP-210 U210BP/146M 420 170 390 20 210 105 140 60 110 2.8 210 ≤50 ≥ 50 10.4
INQUIRY
* Tip: If you are interested in our products, please leave us a message here, we will contact you within one working day and provide a free quotation, please check your email.
Related Products
Standard type disc suspension tempered glass insulator
Standard insulators, as the name implies, refer to insulators designed, manufactured and widely used in accordance with national or international standards.
Pollution-resistant disc suspension tempered glass insulator
The anti-pollution type disc suspension tempered glass insulator is a kind of efficient and reliable electrical equipment, which is mainly used in high voltage transmission lines.
DC type disc suspension tempered glass insulator
Toughened glass insulators with excellent pollution resistance, high strength, good self-cleaning and environmental protection characteristics show great application potential and value in the power industry.
Double Umbrella Disc Suspension Tempered Glass Insulator
As an important part of the power transmission system, the stability and reliability of its performance are directly related to the safe operation of the power grid.